Set application range

Set application range

Catalog sheet: 2.5-1.1

Application range of individual sets with basic accessories

Total length necessary to install and operate the system (metered along the axis of the loading chamber):
300 mm
Maximum protrusion of the balloon: (metered from the edge of the loading chamber):
800 mm
Maximum width (metered from the axis of the loading chamber):
50 mm
Weight of the assembled set/weight including the transport box:
1,8 – 3,0 kg / 6 - 8 kg (depending on the set outfit)

SURVEY OF THE APPLICATION RANGE OF INDIVIDUAL SETS WITH BASIC ACCESSORIES:
Set Closed pipeline
inter. diameter
Connection
thread dim.
Number and type of rubber closing balloons per set Catalogue No.
         
UDP-F1/1 20 to 32 mm G 3/4" to G 5/4" 2x UDP-F1/M 251-1100-001
UDP-F1/2 32 to 65 mm G 5/4" to G 21/2" 2x UDP-F1/V 251-1100-002
UDP-F1/3 32 to 80 mm G 5/4" to G 3" 2x UDP-F1/VV 251-1100-003
UDP-F1/4 20 to 65 mm

G 3/4" to G 21/2"

1x UDP-F1/M + 1x UDP-F1/V 251-1100-004
UDP-F1/5 20 to 80 mm G 3/4" to G 3" 1x UDP-F1/M + 1x UDP-F1/VV 251-1100-005
UDP-F1/6 32 to 80 mm G 5/4" to G 3" 1x UDP-F1/V + 1x UDP-F1/VV 251-1100-006
UDP-F1/7 20 to 80 mm G 3/4" to G 3" 1x UDP-F1/M + 1x UDP-F1/V + 1x UDP-F1/VV 251-1100-007