FASTRA, s.r.o. / Accessories, examples of installation

Accessories, examples of installation

To ensure proper and faultless installation of combined household connections, it is necessary to use accessories supplied by the system manufacturer and observe the installation procedures. It is namely the use of Schuck Beto Fix sealing plaster, which guarantees that the required parameters of transmission through the outer wall are met.

No. Name Intended for Catalogue No.
  Wall disk ARO, yellow, DN25 HSP - gas 610-4000-025
  Wall disk ARO, yellow, DN32/DN40 HSP - gas 610-4000-032
1 Wall disk ARO, yellow, DN50
Wall disk ARO, black, DN25/DN32
HSP - gas
WHP - water
610-4000-050
610-4010-025
  Wall disk ARO, black, DN40 WHP - water 610-4010-040
  Wall disk ARO, black, DN50 WHP - water 610-4010-050
  Wall disk ARO, DN25   610-4020-025
2 Pull-out protection plate ARP, DN32/DN40   610-4020-032
  Pull-out protection plate ARP, DN50   610-4020-050
3 Sealing ring for ARO from EDPM DN25 DN50   610-4030-025
4 Sealing ring for ARO from foam DN25 DN50   610-4040-025
  Wall finishing set No.1 HSP-gas DN25 a WHP-water DN25/DN32 610-4050-025
  Wall finishing set No.2 HSP-gas DN32-DN50 a WHP-water DN40/DN50 610-4050-032
5 Wall finishing set No.3
Sealing ring for ARO from foam No.1
HSP-gas DN50 a WHP-water DN50
HSP-gas DN25 a WHP-water DN25/DN32
610-4050-050
610-4060-025
  Sealing ring for ARO from foam No.2 HSP-gas DN32/DN40 a WHP-water DN40 610-4060-032
  Sealing ring for ARO from foam No.3 HSP-gas DN25-DN50 a WHP-water DN25-DN50 610-4060-050
6 Centering ring DN25-DN50   610-4070-025
  Schuck-Beto-Fix 2kg   610-4080-002
7 Schuck-Beto-Fix 12 x 2kg   610-4080-012
  Schuck-Beto-Fix 25kg   610-4080-025
8 Cartridge gun   610-4000-010
INSTALLATION PROCEDURE

příklady

  1. Insert the bushing into the drilled or cut hole in the wall so that the retaining plate seats on the wall surface.
  2. Place the mounting plate onto the bushing end with threaded part and clamp it using the clip. Then place the clamping nut and clamp it as well.
  3. Align the bushing in the hole (the funnel on the mounting plate must be on top), tighten the clamping nut to securely press the mounting plate onto the wall surface and pour the sealing plaster Schuck Beto Fix into the funnel.
  4. During setting of the mortar (approx. 15 min.), you can continue installing the piping. The mounting plate with clamping nut can be removed after the plaster sets, or later. The retaining plate remains on the inner surface of the building’s wall.

EXAMPLES OF INSTALLATION

příklady

Example 1:
If the hole is precisely drilled, you can use
two ARO retaining plates and concrete
injecting pump for installation.
    Example 2:
If the hole is drilled or cut and its walls are slightly
damaged, use the ARO retaining plate and a mounting
plate for installation.


příklady

Example 3:
In case of uneven hole of up to 250mm in
diameter, you can use mounting plates on
both sides for installation.
    Example 4:
In case of uneven hole of over 250mm in diameter,
place the auxiliary retaining plates and continue as in
Example 3.
7-03-2020, 15:12