A patch for repairing pipes of FZV type (hereinafter referred to as a patch) is used to repair locally damaged steel pipelines (e.g. damaged by corrosion or mechanical impact) with no leakage of medium or with leakage of medium, with the highest value of operating pressure up to 40 bar.
Other dimensions should be consulted
Permissible overpressure of medium in the damaged piping when the patch is being applied:
max. 500 kPa
Permissible leakage of medium out of the damaged piping when the patch is being applied:
max. 50 m3/hour
For other technical parameters following 5.2
TABLE OF STANDARD DIMENSIONS
Name - dimension | D [mm] |
L [mm] |
Patch width | Patch wall | Inner side | Catalogue No. | |||
A [mm] |
O | S [mm] |
bevel 45° /X [mm] |
K [mm] |
Y [mm] |
||||
Patch FZV DN50 x 150 | 60,3 | 150 | 100 | 1/2 | 5,0 | 1,6 | 15 | 5 | 520-2115-060 |
Patch FZV DN65 x 150 | 76,1 | 150 | 130 | 1/2 | 520-2115-076 | ||||
Patch FZV DN80 x 150 | 88,9 | 150 | 100 | 1/3 | 6,3 | 1,6 | 520-2115-088 | ||
Patch FZV DN80 x 300 | 300 | 150 | 1/2 | 520-2130-088 | |||||
Patch FZV DN80 x 500 | 500 | 150 | 520-2150-088 | ||||||
Patch FZV DN100 x 150 | 108 | 150 | 115 | 1/3 | 7,1 | 1,7 | 20 | 10 | 520-2115-108 |
Patch FZV DN100 x 300 | 300 | 180 | 1/2 | 520-2130-108 | |||||
Patch FZV DN100 x 500 | 500 | 180 | 520-2150-108 | ||||||
Patch FZV DN125 x 150 | 133 | 150 | 145 | 1/3 | 6,3 | 1,6 | 520-2115-133 | ||
Patch FZV DN125 x 300 | 300 | 145 | 520-2130-133 | ||||||
Patch FZV DN125 x 500 | 500 | 145 | 520-2150-133 | ||||||
Patch FZV DN150 x 150 | 159 | 150 | 125 | 1/4 | 7,1 | 1,7 | 30 | 520-2115-159 | |
Patch FZV DN150 x 300 | 300 | 170 | 1/3 | 520-2130-159 | |||||
Patch FZV DN150 x 500 | 500 | 170 | 520-2150-159 | ||||||
Patch FZV DN200 x 150 | 219,1 | 170 | 170 | 1/4 | 7,1 | 1,7 | 30 | 10 | 520-2115-219 |
Patch FZV DN200 x 300 | 300 | 230 | 1/3 | 520-2130-219 | |||||
Patch FZV DN200 x 500 | 500 | 230 | 520-2150-219 | ||||||
Patch FZV DN250 x 150 | 273 | 175 | 175 | 1/5 | 10,0 | 2,5 | 520-2115-273 | ||
Patch FZV DN250 x 300 | 300 | 220 | 1/4 | 520-2130-273 | |||||
Patch FZV DN250 x 500 | 500 | 295 | 1/3 | 520-2150-273 | |||||
Patch FZV DN300 x 150 | 323,9 | 170 | 170 | 1/6 | 40 | 520-2115-323 | |||
Patch FZV DN300 x 300 | 300 | 205 | 1/5 | 520-2130-323 | |||||
Patch FZV DN300 x 500 | 500 | 350 | 1/3 | 520-2150-323 | |||||
Patch FZV DN350 x 200 | 355,6 | 200 | 190 | 1/6 | 520-2115-355 | ||||
Patch FZV DN350 x 300 | 300 | 290 | 1/4 | 520-2130-355 | |||||
Patch FZV DN350 x 500 | 500 | 380 | 1/3 | 520-2150-355 | |||||
Patch FZV DN400 x 200 | 406,4 | 210 | 210 | 1/6 | 520-2120-406 | ||||
Patch FZV DN400 x 300 | 300 | 325 | 1/4 | 520-2130-406 | |||||
Patch FZV DN400 x 500 | 500 | 435 | 1/3 | 520-2150-406 | |||||
Patch FZV DN500 x 200 | 508 | 200 | 200 | 1/8 | 520-2120-508 | ||||
Patch FZV DN500 x 300 | 320 | 320 | 1/5 | 520-2130-508 | |||||
Patch FZV DN500 x 500 | 500 | 545 | 1/3 | 520-2150-508 |
L, A, S, X, K, Y - for dimensions following the scheme
D - outer diameter of the repaired pipeline
O - part of the circuit repaired pipeline covering overlays the patch